Reference
BTU per Square Foot Table by Climate Zone
The rule-of-thumb loads behind every sizing calculator on this site, by climate zone, with the factors that adjust them and the room air conditioner chart.
How to use the table
Find your DOE climate zone, multiply the floor area by the figure in the cooling or heating column, and apply the adjustment factors below. The cooling figures are before occupants and the kitchen; the heating figures are the heat the house loses on the design night, which a furnace’s output, not its input, must match. These are first estimates for an average-insulated house with 8 ft ceilings, compiled from published climate-zone sizing charts. An ACCA Manual J load calculation replaces them for a final equipment choice.
Loads, design temperatures and degree days by zone
| Zone | Example cities | Cooling, BTU/hr per sq ft | Heating, BTU/hr per sq ft | Winter design temperature | Heating degree days | Cooling degree days |
|---|---|---|---|---|---|---|
| 1 hot-humid | Miami, Honolulu | 24 | 20 | 50 °F | 300 | 4,300 |
| 2 hot | Houston, Phoenix, Orlando | 22 | 25 | 35 °F | 1,500 | 2,900 |
| 3 warm | Atlanta, Dallas, Los Angeles | 20 | 30 | 25 °F | 2,800 | 1,800 |
| 4 mixed | Washington DC, St. Louis, Seattle | 18 | 38 | 15 °F | 4,500 | 1,200 |
| 5 cool | Chicago, Denver, Boston | 15 | 45 | 0 °F | 6,300 | 800 |
| 6 cold | Minneapolis, Burlington | 13 | 52 | −10 °F | 7,800 | 500 |
| 7 very cold | Duluth, Fargo | 12 | 60 | −20 °F | 9,500 | 250 |
Design temperatures are typical 99% winter values; degree days are base 65 °F, rounded from NOAA normals for representative cities. For a specific address, use the nearest weather station’s figures.
Adjustment factors
| Factor | Values | Source |
|---|---|---|
| Insulation | 1.2 poor, 1.0 average, 0.85 good | Common sizing-chart practice |
| Ceiling height | +10% for each foot above 8 ft | Common sizing-chart practice |
| Sun | 0.9 shaded, 1.0 average, 1.1 very sunny | ENERGY STAR room AC guidance |
| Windows | 0.95 few, 1.0 average, 1.1 many | Common sizing-chart practice |
| Occupants | +600 BTU/hr per regular occupant beyond two (cooling) | ENERGY STAR room AC guidance |
| Kitchen | +4,000 BTU/hr (cooling) | ENERGY STAR room AC guidance |
Cooling sizes are rounded up to the next half ton, with a minimum of 1.5 tons, and design airflow is 400 CFM per ton (350 in humid climates, 450 in dry ones).
A 1,500 sq ft house in each zone
Average insulation, 8 ft ceilings, three occupants and a kitchen, as the calculators give it:
| Zone | Cooling load | AC size | Heating load (output) | Furnace input at 95% AFUE |
|---|---|---|---|---|
| 1 | 40,600 BTU/hr | 3.5 tons | 30,000 BTU/hr | 40,000 |
| 2 | 37,600 BTU/hr | 3.5 tons | 37,500 BTU/hr | 40,000 |
| 3 | 34,600 BTU/hr | 3 tons | 45,000 BTU/hr | 60,000 |
| 4 | 31,600 BTU/hr | 3 tons | 57,000 BTU/hr | 60,000 |
| 5 | 27,100 BTU/hr | 2.5 tons | 67,500 BTU/hr | 80,000 |
| 6 | 24,100 BTU/hr | 2.5 tons | 78,000 BTU/hr | 100,000 |
| 7 | 22,600 BTU/hr | 2 tons | 90,000 BTU/hr | 100,000 |
ENERGY STAR room air conditioner chart
For window and portable units, sized room by room, before the sun, occupant and kitchen adjustments:
| Room area up to | Capacity | Room area up to | Capacity |
|---|---|---|---|
| 150 sq ft | 5,000 BTU/hr | 700 sq ft | 14,000 BTU/hr |
| 250 sq ft | 6,000 BTU/hr | 1,000 sq ft | 18,000 BTU/hr |
| 300 sq ft | 7,000 BTU/hr | 1,200 sq ft | 21,000 BTU/hr |
| 350 sq ft | 8,000 BTU/hr | 1,400 sq ft | 23,000 BTU/hr |
| 400 sq ft | 9,000 BTU/hr | 1,500 sq ft | 24,000 BTU/hr |
| 450 sq ft | 10,000 BTU/hr | 2,000 sq ft | 30,000 BTU/hr |
| 550 sq ft | 12,000 BTU/hr | 2,500 sq ft | 34,000 BTU/hr |
Portable units deliver less than their ASHRAE label: the real cooling (SACC) is about 55% of it for a single-hose unit and 65% for a dual-hose unit.
Calculators that use these figures
- Cooling: central AC size, window AC size, portable AC size, mini-split size
- Heating: furnace size, heat pump size, boiler size, radiator output, baseboard length, space heater size, radiant floor output, heating cost by fuel
- Costs and planning: degree-day fuel estimate, heat pump vs furnace, setback savings, size check, wall heat loss
The guide to BTU per square foot by climate zone explains the figures and their limits.