Every air conditioner question starts the same way: how much heat enters the space on a hot afternoon, and how fast must the equipment remove it. The answer is a load in BTU per hour, and the first estimate of it is the floor area multiplied by a figure for your climate zone, then adjusted for ceiling height, insulation, sun, windows, people and a kitchen. These calculators do that arithmetic and round the result to the sizes that are actually sold, in half-ton steps for central systems and in the standard BTU classes for room units.

The common mistake is to size up "to be safe". An oversized air conditioner reaches the thermostat setting quickly and shuts off before it has removed much moisture, so the house feels clammy and the compressor wears out on short cycles. Treat every result here as a starting estimate; the standard a contractor follows for the final figure is ACCA Manual J for the load and Manual S for the equipment.

8 calculators

Guides for this topic

Questions people ask

How many tons of AC does a 1,500 square foot house need?
At the rule-of-thumb loads this site uses, a 1,500 sq ft house with average insulation, 8 ft ceilings, three occupants and a kitchen needs about 3 tons in a mixed climate (zone 4), 3.5 tons in a hot climate (zones 1 to 2) and 2 to 2.5 tons in a cool one (zones 5 to 7). Sun exposure, many windows and a poorly insulated attic push the figure up by 10 to 20%; good insulation brings it down a half size. A Manual J load calculation replaces the rule of thumb for the final size.
How many BTU do I need for a 12 by 12 room?
A 144 sq ft room falls in the 150 sq ft class of the ENERGY STAR room air conditioner chart, which calls for about 5,000 BTU per hour. Add 10% if the room is very sunny, subtract 10% if it is heavily shaded, add 600 BTU for each person beyond two who regularly uses it, and add 4,000 BTU if it is a kitchen. A 5,000 or 6,000 BTU window unit is the usual answer.
What size mini-split do I need for a garage?
Garages are sized like any other room, then adjusted for their weak points: uninsulated walls and a big door act like "poor" insulation, and a west-facing door adds sun load. A typical two-car garage of 400 to 500 sq ft lands between 12,000 and 18,000 BTU per hour, which means a 12k or 18k head. If the garage is uninsulated in a hot climate, insulate it first; cooling an uninsulated garage costs more than the insulation.
How much does a higher SEER2 rating save?
Electricity use falls in proportion to the ratio of the ratings. Replacing a 10 SEER system with a 15.2 SEER2 unit cuts cooling electricity by about a third, because 10 ÷ 15.2 is 0.66. For a 3-ton system running 1,200 hours a season at 17 cents per kWh that is roughly $200 a year. The SEER upgrade savings calculator does the sum with your hours and your price, and shows how long the extra cost takes to pay back.
How many CFM of airflow does an air conditioner need per ton?
About 400 cubic feet per minute per ton is the design rule for most of the United States. Humid climates use 350 CFM per ton so the coil runs colder and removes more moisture; dry climates use up to 450. A 3-ton system therefore needs 1,200 CFM through its ducts (1,050 in a humid climate), which is why duct size and return grille size matter as much as the equipment.

More calculators on our other sites

  • Drywalls Calculator

    Sheets, screws, joint compound, tape, corner bead, studs, soundproofing and what hanging and finishing drywall costs.

  • Floorings Calculator

    How much tile, wood, vinyl, carpet, underlayment and trim a floor needs, and what it costs.

  • Paints Calculator

    How much paint, primer, stain and wallpaper a job needs, and what it costs.